9) (oP8) - System Type (Conventional Furnace)
Depending on your home’s heating system, you may need to choose between a conventional
furnace system or an alternative system.
Value 0= Conventional (Default)
Value 1= Alternative (O/B wire active when COOLING)
Value 2= Alternative (O/B wire active when HEATING)
8) (oP7) - Filter Change Reminder
Choose how many hours the furnace will be in use before filter change indicator will display.
Value 0= Disabled (Filter change icon will never display)
Value 1= 500 hours
Value 2= 1000 hours (Default)
Value 3= 2000 Hours
Value 4= 4000 Hours
10) (oP9) - °C or °F Display
Since Celsius (°C) is the default mode, no action is required to use the thermostat in this mode.
Select value “1” for Fahrenheit, before setting any other thermostat settings.
Value 0= Celsius (Default)
Value 1= Fahrenheit